← All Colorado water providers

East End Water Association

East End Water Association is the public water system serving 70 people in Otero County, from groundwater. EPA has no service-area boundary on file for this system, so it cannot be drawn on a map.
Community system · EPA id CO0145120 · filed with EPA as “EAST END WA”
People served
70
Service connections
35
Primary source
Groundwater
Owner
Private
Counties served
Otero
Water district
no boundary on file

Where the water comes from

FacilityKindWater
CHERAW WELLWellGroundwater
NO 1 WELLWellGroundwater

These are EPA's facility records, not DWR structures. Which decreed rights sit behind an intake is the next phase; nothing here is inferred.

DWR structures that name this system

Source Probable join · fetched 2026-09-09 · matched on DWR's recorded contact or an EPA intake name; verify on the dossier

No DWR structure on file records this system as its contact, and none of its EPA intakes matches a structure name in its districts. DWR records a contact on only a fraction of structures, and only for districts fetched from its live service, so this is absence of a record, not evidence of no rights.

Compliance record

Source Register of another agency · fetched 2026-09-09 · verify at EPA ECHO ↗

1 health-based violation open now. A health-based violation means a measured level went over a federal limit, or a required treatment step was not carried out — not a missed form. What that means for anyone drinking the water depends on the contaminant and the dose; read EPA's own report and the system's Consumer Confidence Report rather than anything inferred here.

EPA's own summary: violations in 12 of the last 12 quarters. In violation for, in EPA's words: 0999=Chlorine; 1008=Chlorine dioxide; 4010=Combined Radium (-226 and -228); 8000=Revised Total Coliform Rule. Currently: 4010=Combined Radium (-226 and -228); 8000=Revised Total Coliform Rule.

What happened

All 41 violation records on file, grouped into the 3 distinct things EPA's codes describe. Dates are the compliance period the violation is filed against.

Violation code 2C — Revised Total Coliform Rule health-based 1 open
A required treatment step was not carried out or not proved. 7 records, 2022-01-14 to 2023-01-14.
EPA violation code 2C, contaminant 8000 — not in the code table this build carries.
MCL, Average — Combined Radium (-226 and -228) health-based
A measured contaminant level went over the federal limit. 33 records, 2017-01-01 to 2026-01-01. Highest measured: 10.6 PCI/L against a limit of 5.0.
Rule: Radionuclides -- radium, uranium and gross alpha.
Treatment Technique No Certif. Operator — DBP Stage 1 health-based
A required treatment step was not carried out or not proved. 1 record, 2022-07-01.
Rule: Stage 1 Disinfectants and Disinfection Byproducts Rule.
Every violation record, as filed (12 of 41)
Compliance periodWhatAboutKindStatusMeasured
2026-01-01 – 2026-03-31 MCL, Average Combined Radium (-226 and -228) health-based known, archived 7.0 PCI/L (limit 5.0)
2025-10-01 – 2025-12-31 MCL, Average Combined Radium (-226 and -228) health-based known, archived 7.0 PCI/L (limit 5.0)
2025-07-01 – 2025-09-30 MCL, Average Combined Radium (-226 and -228) health-based known, archived 7.0 PCI/L (limit 5.0)
2025-04-01 – 2025-06-30 MCL, Average Combined Radium (-226 and -228) health-based known, archived 7.0 PCI/L (limit 5.0)
2025-01-01 – 2025-03-31 MCL, Average Combined Radium (-226 and -228) health-based known, archived 7.0 PCI/L (limit 5.0)
2024-10-01 – 2024-12-31 MCL, Average Combined Radium (-226 and -228) health-based known, archived 7.0 PCI/L (limit 5.0)
2024-07-01 – 2024-09-30 MCL, Average Combined Radium (-226 and -228) health-based known, archived 7.0 PCI/L (limit 5.0)
2024-04-01 – 2024-06-30 MCL, Average Combined Radium (-226 and -228) health-based known, archived 6.95 PCI/L (limit 5.0)
2024-01-01 – 2024-03-31 MCL, Average Combined Radium (-226 and -228) health-based known, archived 7.4 PCI/L (limit 5.0)
2023-10-01 – 2023-12-31 MCL, Average Combined Radium (-226 and -228) health-based known, archived 7.38 PCI/L (limit 5.0)
2023-07-01 – 2023-09-30 MCL, Average Combined Radium (-226 and -228) health-based known, archived 7.33 PCI/L (limit 5.0)
2023-04-01 – 2023-06-30 MCL, Average Combined Radium (-226 and -228) health-based known, archived 8.5 PCI/L (limit 5.0)

The remaining 29 are on the ECHO report.

What the regulator did about it

162 enforcement actions on this system's federal record. In Colorado the state is the primacy agency, so most actions are the state's; EPA acts directly on tribal systems and when it steps in.

DateActionBy
2026-03-17 St Violation/Reminder Notice state
2025-12-17 St Compliance achieved
System reported TC and associated chlorine residual samples for NOV2025 late on 12.12.25 RNK 12.16.25
state
2025-12-16 St Violation/Reminder Notice state
2025-12-16 St Violation/Reminder Notice state
2025-12-16 St Public Notif requested state
2025-12-16 St Violation/Reminder Notice state
2025-12-16 St Public Notif requested state
2025-12-12 St Compliance achieved
System reported TC and associated chlorine residual samples for NOV2025 late on 12.12.25. SOX applied RNK 12.16.25
state
2025-09-24 St Violation/Reminder Notice state
2025-04-09 St Violation/Reminder Notice state
2024-12-19 St Violation/Reminder Notice state
2024-11-15 St Violation/Reminder Notice state
2024-11-15 St Public Notif requested state
2024-11-01 St Violation/Reminder Notice state
2024-11-01 St Public Notif requested state
2024-10-30 St Compliance achieved state
2024-10-14 St Compliance achieved state
2024-08-30 St Violation/Reminder Notice state
2024-05-30 St Violation/Reminder Notice state
2024-03-12 St Violation/Reminder Notice state

20 most recent of 162; the rest are on the ECHO report.

Lead and copper

The latest 90th-percentile lead result is 0.0 mg/L (sampling period ending 2025-12-31) against an action level of 0.015 mg/L, below it. 6 results on file.

The action level is not a health limit: it is the level at which the rule requires a system to act (corrosion control, public education, and in some cases replacing lead service lines). Lead mostly enters water from household plumbing, so a system-wide percentile does not tell you what comes out of one tap.

Violation, enforcement and lead/copper records are EPA SDWIS federal reporting, fetched monthly; the summary is EPA ECHO. Code names come from EPA's own REF_CODE_VALUE table. SDWIS carries violations, not routine sample results — nitrate, disinfection by-product and PFAS values are not in it, and a clean record here means nothing was reported as a violation, not that nothing was ever detected. For what was measured, ask the system for its Consumer Confidence Report.

PFAS and lithium: EPA's UCMR 5 monitoring, 2023–2025

Source Register of another agency · fetched 2026-09-09 · verify at EPA UCMR occurrence data ↗

EPA did not sample this system under UCMR 5 (the rule covered every system serving more than 3,300 people and a drawn sample of smaller ones).

Common questions

Who provides drinking water in La Junta, Colorado?

East End Water Association is the public water system serving 70 people in Otero County, from groundwater. Its EPA public water system id is CO0145120.

Where does East End Water Association get its water?

East End Water Association reports groundwater as its primary source. EPA lists its source facilities as CHERAW WELL, NO 1 WELL.

Does East End Water Association have any drinking water violations?

EPA's compliance record shows no open health-based violations for East End Water Association at the last monthly fetch. Older and non-health-based entries, if any, are listed on this page.

Every provider in Otero County.

The record

EPA SDWIS federal reporting as of 2026-09-08; the compliance record above is EPA's own, fetched monthly, and the ECHO report carries the rest. Report a problem →